Dosimetric characteristics and optimization for a multislice computed tomography

dc.contributor.authorBalamurali, S.
dc.date.accessioned2024-10-03T06:04:45Z
dc.date.available2024-10-03T06:04:45Z
dc.date.issued2009
dc.description.abstractThis is the first study in the National Cancer Institute, Sri Lanka to evaluate dose measurements with Head and Body phantoms in Toshiba Acquilion Computed Tomography (CT) Simulation which is one and only large bore CT scanner in the whole Island. Results from this study were compared with EU reference dose levels for CT, compiled from ACR, IAEA, NRPB and UK [5]. The measured dosimetric quantities are weighted computed tomography dose index (CTDIᵩ), dose length product (DLP) andeffective dose (E). The radiation risk factors were compared with European guidelines (data obtained from ICRP 60) with different age groups of patients such as 0 — 5 yrs, 5-10 yrs and adults with standard SURE MODE CT exposure of clinical practice. It is found that the risk associated in head phantom studies for infant age group (0 — 5 yrs) effective doses varies from 14.92 - 38.8 %, child age group (5 - 10 yrs) effective doses varies from 71.43 - 122.37 % and adult age group effective doses varies from 15.2 - 40 % , while for body phantom the estimation of effective dose risk, infant age group (0 - 5 yts) varies from 16.98 - 66.50 % , child age group (5 - 10 yrs) varies from 108.87 - 138.97 % and there is no deviation observed for adult age group. It is noted that percentage variation is higher due to smaller beam collimation and higher mAs values. It is found that the pediatrics in the age group (5 - 10 yrs) is more prone to risk due to biological phase, perhaps the focal spot was analyzed through Linear Regression Graphs,there is no discontinuity observed in nCTDI values. It is concluded that justification of practice should be implemented in special procedures like IMRT, SRS and SRT. Then the dose optimization should be calculated for the entire treatment schedule. Our study has confirmed the great impact of technical factors and acquisition parameters on CTdoses. The provided comprehensive dosimetric data will facilitate the dose-effective use of the scanner study.
dc.identifier.urihttps://ir.lib.pdn.ac.lk/handle/20.500.14444/1416
dc.language.isoen_US
dc.publisherUniversity of Perareniya
dc.subjectPhysics
dc.subjectMedical Physics
dc.titleDosimetric characteristics and optimization for a multislice computed tomography
dc.typeThesis

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Balamurali 2009.pdf
Size:
273.67 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections