Dosimetric and clinical characteristics of multi-leaf collimator in radiation therapy

dc.contributor.authorRajaratnam, D.
dc.date.accessioned2024-10-03T06:28:46Z
dc.date.available2024-10-03T06:28:46Z
dc.date.issued2011
dc.description.abstractThe role of Multi Leaf Collimator (MLC) has changed rapidly in recent year for the treatment techniques of Three Dimensional Conformal Radiation Therapy (3D-CRT) and Intensity Modulated Radiation Therapy (IMRT) since its entry was to replace the customized alloy shielding blocks. In some clinical cases, large area of extended leaves are used without jaws and also MLCs are used instead of jaws. However, most of the beam characteristics of MLCs are not similar to jaws. Therefore, the dosimetric and clinical analysis was carried out for three field defining methods of MLC only, JAW only and JAW+MLC. The parameters such as percentage surface dose, buildup region, penumbra width, dosimetric field width, quality index, absolute output, total scatter factor, percentage of transmission were measured for 2300C/D Varian linear accelerator with millennium 80 leaves MLC using tadiation field analyser, 0.125cc/0.6ec ionization chamber with electrometer and compared with varying field sizes of 6 MV and 15 MV photon beams. The variation of surface dose with MLC only field for 6 MV is 15.1% and 20.6% for 15 MV from small to large field sizes. Penumbra for MLC only field is about 1mm higher than the other two fields, Inline Collimator 90° setup shows an overall increase in the penumbra widths compared to cross line Collimator 0° setup for each field defining methods. The percentage of transmission through carriages is <1.5%. however, there is no significant difference inthe above discussed parameters between JAW and JAW+MLC fields. With improving radiotherapy techniques, the function of the MLC is critical and complex. Therefore, it is necessary to verify the parameters of MLC periodically by following the quality assurance surveillance protocols. Mechanical and dosimetric dynamic MLC (dMLC) quality assurance tests carried out for this machine is well within the tolerance limits. Pre-treatment clinical evaluation was done for a dMLC IMRT plan using independent dose verification and Gamma analysis which gives the details of comparative profile analysis of planned and delivered dose and Distance To Agreement (DTA) for dMLC.
dc.identifier.urihttps://ir.lib.pdn.ac.lk/handle/20.500.14444/1417
dc.language.isoen_US
dc.publisherUniversity of Peradeniya
dc.subjectRadiation therapy
dc.subjectMulti Leaf Collimator MLC
dc.subjectDosimetric characteristics
dc.titleDosimetric and clinical characteristics of multi-leaf collimator in radiation therapy
dc.typeThesis
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Rajaratnam 2011.pdf
Size:
2.72 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description:
Collections