Ct number - electron density conversion relationship : effect of tissue inhomogenity on dose

dc.contributor.authorNawas, F. F.
dc.date.accessioned2024-09-06T03:05:00Z
dc.date.available2024-09-06T03:05:00Z
dc.date.issued2014
dc.description.abstractThe main aspect of an imaging technique is the ability of incorporating the tissue inhomogeneity corrections to the dose calculations. This could be fulfilled only if the relationship between the CT number and the electron density is established for each CT scanner used in a facility. This study describes a method of establishing a relationship between the CT number and the electron density and the effect of a tissue inhomogeneity on the dose distribution. An electron density reference phantom with 17 different tissue substitutes was scanned using the Siemens Somatom Sensation Open CT scanner to establish the relationship between the CT number and the electron density. These images were downloaded to the Nucletron Oncentra Master Plan v3.3 SPI treatment planning system. At the treatment planning workstation the average CT number of each insert was determined. The mean CT value was plotted against the relative electron density of the tissue equivalent insert. A linear relationship was obtained between the CT number and the relative electron density separately for CT numbers between -1000 to 0 and 0 to 1000 To investigate the dose distribution due to a tissue inhomogeneity the electron density reference phantom was scanned using the Siemens Somatom Sensation Open CT scanner. A randomly chosen tissue insert of the phantom was replaced by a metal insert and the scan was repeated. A treatment plan was done for the images with and without the metal insert at the treatment planning workstation. The isodose distribution map and the dose - volume histograms (DVH) of the two images were compared. With the metal insert 50% of the PTV received a dose greater than that of the dose received without the metal insert. The dose coverage is affected by tissue inhomogeneity, leading to changes in the dose distribution. This leads to geometrical misses of the target. Therefore, to maximize the therapeutic benefit of radiation therapy it is important to investigate the difference in the dose distribution due to tissue inhomogeneity.
dc.identifier.urihttps://ir.lib.pdn.ac.lk/handle/20.500.14444/723
dc.language.isoen_US
dc.publisherUniversoty of Peradeniya
dc.subjectTissue inhomogeneity
dc.subjectCT number
dc.subjectElectron density
dc.titleCt number - electron density conversion relationship : effect of tissue inhomogenity on dose
dc.typeThesis
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Nawaz 2014.pdf
Size:
430.16 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description:
Collections