Evaluation of effective radiation dose to the male gonads during high resolution chest computed tomography examinations

dc.contributor.authorWickramasinghe, H.H.S.
dc.contributor.authorUdayangani, R.K A.
dc.contributor.authorPerera, M.G.R.S.
dc.date.accessioned2025-10-17T05:56:22Z
dc.date.available2025-10-17T05:56:22Z
dc.date.issued2024-08-29
dc.description.abstractMedical radiation imaging carries vital benefits to the mankind along with its inherent inevitable radiation risks. When considering the close proximity of the region of interest to the imaging field, possible radiation exposure to the male gonads during Computed Tomography (CT) chest examinations warrants careful scrutiny of gonadal radiation dose. Hence this study aimed to evaluate the effective radiation dose to the male gonads during CT Chest examinations. This quantitative study assessed the gonadal radiation dose in HRCT chest exams with and without lead shielding, while investigating the impact of shielding on image quality. The study was carried out in the National Hospital Kandy, Sri Lanka, from August 2023 to October 2023. Gonadal dose was compared with and without 0.5mm lead shielding of 26 patients who underwent HRCT chest examinations using an electronic dosimeter. Image quality was assessed with RadiAnt DICOM Viewer, and data were analyzed using Minitab software. The study results revealed a substantial reduction in radiation dose to male gonads with lead shielding during HRCT chest examinations. Without shielding, the mean equivalent dose was 0.08104 mSv, which decreased to 0.02838 mSv with shielding. The effective dose dropped from 0.0064832 mSv to 0.0017028 mSv, aligning with ICRP recommendations. Statistical analysis confirmed significant reductions (p < 0.05), with a 64.98% decrease in radiation dose with proper lead shielding. Also, it was confirmed that there was no proof of image deterioration caused by the lead shielding. In conclusion, there is significant effective radiation dose to male gonads during HRCT chest examinations which can be evidently reduced with the use of proper lead shielding without degrading the image quality.
dc.identifier.citationProceedings of the Peradeniya University International Research Sessions (iPURSE) – 2024, University of Peradeniya, P 22
dc.identifier.issn1391-4111
dc.identifier.urihttps://ir.lib.pdn.ac.lk/handle/20.500.14444/5508
dc.language.isoen_US
dc.publisherUniversity of Peradeniya, Sri Lanka
dc.subjectHRCT Chest
dc.subjectGonadal Radiation Dose
dc.subjectShielding
dc.subjectRadiation Protection
dc.titleEvaluation of effective radiation dose to the male gonads during high resolution chest computed tomography examinations
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Wickramasinghe, H.H.S.pdf
Size:
236.52 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections